Every sachet dose between 2 g and 20 g owes the same fill tolerance, 10 % of the labeled quantity. NIST Handbook 133 puts every package under 36 g into one row of one table.
A 5 g chili blend, a 5 g supplement granule and a 5 g instant juice powder all owe the identical 0.5 g. What differs is which physical property attacks that target.
The filling accuracy depends on the material in the hopper before it depends on the doser on the quotation. Flow class governs the seasoning line, particle-size ratio governs the granule line, and moisture uptake governs the drink powder line.
NIST Handbook 133 sets the maximum allowable variation, or MAV, for any package under 36 g at 10 % of labeled quantity. A 2 g sachet may miss by 0.2 g and a 5 g sachet by 0.5 g.
Three consequences follow, all of them quotation line items.
Padding every dose to clear that first test is permanent product giveaway.
Servo motors do not produce fill accuracy on their own. Accuracy comes from closed-loop weight feedback, where the checkweigher corrects the doser instead of only rejecting the sachet.
Percentage tolerance tightens as dose mass falls, so a plus-minus figure taken on multi-kilogram fills describes an easier problem than a 5 g sachet. Ask what dose the number came from before putting two sachet packing machine quotations side by side.
Five commercial seasoning blends measured on GranuHeap and GranuPack instruments span a Hausner ratio of 1.15 to 1.57 and a bulk density of 0.440 to 0.780 g/ml. That is free-flowing to barely flowing inside one portfolio.
| Blend | Bulk density (g/ml) | Tapped density (g/ml) | Hausner ratio |
|---|---|---|---|
| Injection mix | 0.780 | 0.930 | 1.19 |
| Hot marinade | 0.659 | 0.755 | 1.15 |
| Herb marinade | 0.560 | 0.684 | 1.22 |
| Bratwurst | 0.481 | 0.755 | 1.57 |
| Chip seasoning | 0.440 | 0.585 | 1.33 |
A volumetric doser meters volume, not mass. Running the injection mix at a cup setting calibrated on the chip seasoning puts 77 % more product into every sachet.

Angle of repose runs from about 50° to over 70° across those samples, and high-oil chili blends sit at the cohesive end. Cohesive powder bridges above the auger, clings to the screw flights and builds up on contact surfaces.
Salt loads those same surfaces a second way. Chloride attacks the passive film that keeps stainless steel stainless, and 316L carries 2-3 % molybdenum against that breakdown where 304 carries none. Pitting starts in crevices: hopper seams, auger bearings, un-passivated welds.
Specify alloy by part rather than by machine. 304 on non-wetted structure with 316L on every product-contact surface puts the premium where the salt actually lands.
The second handle is surface finish. Food-contact surfaces should be 0.8 µm Ra or better, because a rougher surface holds oleoresin-bearing residue, which is both the buildup mechanism and a corrosion site.
Name the standards on the RFQ: ASTM A240 or EN 10088 for the alloy certificate, and FDA 21 CFR 117.40, NSF/ANSI 51 or 3-A for food-contact suitability.
No single doser calibration holds across that spread. A platform such as the TL-SA-140 sachet packing machine stores a separate dosing calibration per material profile across its servo axes. A spice run and a nutraceutical batch then change over without a mechanical rebuild.
Sifting segregation needs a particle-size ratio of at least 1.3:1 between an active and its carrier, plus free-flowing behaviour and a velocity gradient that lets fines fall through the void spaces. A low-dose supplement blend usually supplies all three.
Matching particle size is not a sufficient defence. In aspirin and excipient blend trials, the mix with the smallest size difference segregated the worst, because particle interactions run alongside size. Density difference alone will separate a size-matched blend.
A batch that passes blend uniformity before filling and fails it after locates the cause in the filling operation, not the blend.
Four machine-side variables carry the load:

ASTM sifting and fluidization indices did not translate directly into content-uniformity outcomes in tablet work, so treat them as a screen rather than a verdict.
Instant drink and juice powders take up moisture from the room, and moisture changes bulk density. A volumetric setpoint holds the cup, not the grams, so delivered mass drifts while the setting sits untouched.
The bench test can miss this entirely. Caked samples measure less cohesive than fresh powder, because agglomerates raise the effective particle size and pull the measured cohesive index down.
A flow test that passes on a drum left open for a week is the exact case where the auger jams.
Sealing the hopper behind dehumidified or nitrogen-purged air keeps the powder from changing between calibration and run. Holding the forming tube above dew point keeps condensate out of the seal zone, and ionising air at the fill tube stops static.
Where the powder is genuinely hygroscopic, the choice between a volumetric and a gravimetric dosing system stops being a cost question. Volumetric metering cannot see the density change. A gravimetric loop weighs the dose and corrects for it.
Run the acceptance trial on the worst-flowing SKU in the portfolio, with material from an opened drum rather than a fresh laboratory sample. That is the combination the doser will meet on a wet Tuesday in month three.
A percentage accuracy figure quoted without the fill weight it was measured at is not a specification. Material characterisation narrows the machine choice; it does not settle it.
The calibration you are really buying belongs to a material profile, not to a machine. Count how many profiles the control system can store before you compare accuracy lines.