A sachet failing leak test at end of line is rarely a single defect — it is one of five symptoms sharing a small set of upstream root causes. Operators who reach for jaw temperature first spend shifts cooking film around problems that started at the auger, the forming collar, or a $5 strip of PTFE tape.
The five defects below are ordered by how often they get misdiagnosed. Each follows the same triage shape: symptom, cause, confirming check, fix.
A sachet that looks fine at the discharge but fails a downstream leak test almost always has a channel leak. Contamination is the first place to look — not jaw temperature.
Visual checks catch seal channels down to 75 µm with only a 60-100% probability, so some leak defects pass without visible clues. ASTM F1886 visual inspection is a first-line screen only, not a pass gate.
Powder dust migrating from the auger discharge or static-charged film during unwind settles into the seal zone and acts as a physical barrier. The sealant layers cannot touch, and no chemical bond forms regardless of setpoint.
Run a thumb along the inside of the seal area. If you feel grit or powder, jaw temperature is innocent. Confirm with ASTM F3039 dye-penetration — channel leaks down to ~50 µm light up within minutes, and the dye trail points to the contamination path.
The fix is upstream: add compressed-air blow-off above the seal jaws on dusty products, fit a static eliminator over the film web to neutralize static, and inspect the auger discharge for splash. Cleaning the jaws is the symptom remedy; controlling where the powder lands is the cause remedy.

When the seal area shows a visible wrinkle or fold, the failure is upstream of the jaws. A wrinkle forms a channel leak because the leak path runs along the wrinkle, several times wider than the channel diameter the seal was designed for.
Jaws sealing through doubled or tripled film cannot bond properly even at correct temperature and dwell. Cranking temperature higher burns surrounding film without fixing the wrinkled section.
Most wrinkles trace to loose unwind tension, a worn dancer arm, or forming-collar misalignment. If the wrinkle direction is consistent across rejects, the collar geometry is wrong; if random, the tension control is drifting.
Adjust unwind tension first (most lines need 0.5-1.5 N per cm of film width), reseat the forming collar, then verify jaw parameters. Operators who default to “+10 °C and see if it holds” on wrinkle defects damage three rolls of film before realizing the wrinkle is still there.

A seal that peels apart in the operator’s hand is the cleanest defect on this list — the diagnosis is heat, dwell, or pressure, and the fix is at the jaw. The seal failed to reach activation temperature for long enough at sufficient contact pressure, so the sealant layers softened without fusing.
Pull a peeled sachet apart and look at the seal face. A glossy, unmelted surface means the jaw never reached activation temperature — increase setpoint 5-10 °C.
A partially melted surface with peel-after-some-resistance means dwell was too short — extend dwell 100-200 ms before raising temperature. A complete melt pattern with weak adhesion means contact pressure is insufficient — inspect the rubber pad behind the jaw and check pneumatic pressure.
Change one variable per trial. Operators who turn three knobs together cannot tell which fixed the seal.
Heat-dwell-pressure is the foundation of every sachet packaging machine sealing system. Quantify seal strength against an ASTM F88 peel-strength baseline so adjustments target a measurable value.

A seal with stringy edges, scorched film, or a crumbly texture has an over-heat problem — but the root cause is rarely the setpoint itself.
The most common cause of stringy seals on automated sachet lines is worn or torn PTFE (Teflon) tape on the heating element. A $5 strip of tape, replaced in 60 seconds, prevents thousands of dollars in downtime.
Open the jaw guard and inspect the PTFE strip on both seal bars. Look for tears, glazed patches, or sections where the tape has shifted off the heating element.
If the tape is intact, check whether the burnt pattern is uniform. Uniform scorch suggests over-temperature (reduce setpoint 5-10 °C); one-sided scorch points to misaligned jaws pinning one section against the heater.
Replace the PTFE tape at every changeover as preventive maintenance, not corrective action.

On a multi-lane sachet line, an aggregate checkweigher reading “in spec” can hide a single lane drifting badly out of spec — the average masks the offender. Sachet weight variance regularly exceeds the variance of a single dosed unit, so aggregate weight checks cannot resolve which lane is misfilling.
Pull 10 sachets from each lane separately, weigh them individually, and chart by lane. If one lane shows a consistent offset while the others sit on target, the auger or volumetric cup for that lane is the cause — check for product bridging, worn flights, or a stuck cup.
If all lanes drift together, the upstream feed is the cause, not the dosing.
Multi-lane sachet systems with independent lane control allow isolating the affected lane and adjusting its fill parameter while the others run on target. Lines without lane-level control need a per-lane checkweigher upstream of the seal, not an aggregate one downstream.

Three reflexes account for most of the wasted troubleshooting time on sachet quality control:
The broader troubleshooting discipline across packaging machinery follows the same rule: name the symptom precisely before turning a knob.

The most common QC mistake on sachet lines is treating each defect as a one-off, instead of building a fixed sampling cadence. The cadence that catches problems early is start of shift, once per hour, after any adjustment or material changeover, and end of shift.