Types of Pharmaceutical Packaging

Pharmaceutical packaging is sorted into three layers by a single test: contact with the drug. Primary packaging touches the dosage form — blisters, strips, bottles, ampoules, vials, syringes, cartridges, sachets and tubes. Secondary packaging surrounds it without contact — the folding carton, its label and the leaflet. Tertiary packaging moves the cartons through the supply chain — shipping cases, pallets and, for temperature-sensitive product, insulated or refrigerated shippers.

If you already run food lines, the machine principles carry over — a pharmaceutical sachet is still form-fill-seal — but the requirements are stricter at every step, and packaging equipment has to be validated like any other process step in the plant.

Primary Pharmaceutical Packaging

Primary packaging is the component in direct contact with the dosage form, so it carries two jobs at once: it must not react with or absorb the formulation, and it sets the barrier against moisture, oxygen, light and microbial contamination. The format follows the dosage form; the ten in general use are below.

Packaging typeTypical applicationsMain advantages
Blister packsTablets, capsulesUnit-dose protection, tamper evidence, portability
Strip packsTablets, capsulesDoses tear off along perforations; foil/foil strips give high moisture barrier
Glass bottlesLiquids, tablets, powdersExcellent chemical resistance and barrier properties
Plastic bottlesTablets, capsules, syrupsLightweight and impact resistant
AmpoulesInjectable medicinesHermetically sealed, strong contamination protection
VialsVaccines, injections, powdersSuitable for single- or multi-dose products
Prefilled syringesInjectable drugs, biologicsConvenient dosing and reduced preparation
CartridgesInsulin, dental anesthetics, injectable medicinesCompatible with pens and injection devices
Sachets and pouchesPowders, granules, liquidsLightweight and suitable for individual doses
TubesCreams, gels, ointmentsConvenient dispensing and product protection

Choosing between them comes down to the degree of protection the product needs, compatibility with the contents, the filling method and cost — plus presentation and ease of opening for over-the-counter products.

Sachets and stick packs are the one format on the list that runs on the same form-fill-seal principle as food packaging, which is why OTC and nutraceutical powders and granules usually go on a stick pack machine or sachet machine rather than a blister line, with the laminate chosen for barrier.

Secondary Pharmaceutical Packaging

Secondary packaging is everything that surrounds the primary container without touching the product — the folding carton, the label and the patient leaflet — and it is the layer on which serialization and tamper evidence are applied, so the regulated print-and-verify work on a line lands here.

In the EU, Delegated Regulation (EU) 2016/161 requires two safety features on the outer pack of prescription medicines (the immediate pack when there is no outer pack). The first is a unique identifier carried in a Data Matrix barcode: product code, a serial number of up to 20 characters, batch number, expiry date, and a national reimbursement number where a member state requires one. The second is an anti-tampering device.

The code is printed and read back at the cartoner, and every pack must be verified as readable and correct before release. The anti-tampering device — a seal label, a glued flap or a tuck-in closure — must show visibly when broken and must not break under normal handling for the product’s whole shelf life.

In the US, the DSCSA product identifier does the same job, in human-readable form and in a 2D Data Matrix on each package, meaning the smallest saleable unit. On secondary packaging lines built for either market the cartoner is therefore the same intermittent- or continuous-motion machine used for food, with a printer, a verification camera, a leaflet feeder and a tamper-seal station added.

Tertiary Pharmaceutical Packaging

Tertiary packaging is the transport layer — shipping cases, stretch-wrapped pallets, and insulated or refrigerated shippers for temperature-sensitive product — and it is specified by WHO’s storage and transport guidance rather than by WHO’s packaging guideline, which excludes outer packaging used for transport from its definition of packaging material.

Its job is mechanical and thermal. The case or shipper has to protect the cartons against damage and against the ambient temperature range they will meet in transit, close in a way that lets the recipient see the load was not tampered with — shrink-wrapped pallets, locked containers — and carry a label stating the transport temperature range and the handling orientation.

The temperature class on the product label decides the system. Normal storage is 15–25 °C, or up to 30 °C depending on climate; refrigerated product is held at 2–8 °C, frozen product at –5 to –20 °C, and deep-frozen product below –18 °C.

Room-temperature product ships in ordinary cases and pallets. Everything colder needs either an active system — powered, thermostatically controlled refrigerated trucks and containers — or a passive one: an insulated shipper holding a finite charge of gel packs, phase-change material or dry ice, qualified for an exact packing configuration and load.

Freeze-sensitive product packed with frozen coolant must be kept from dropping below 0 °C, which is a packing-configuration rule rather than a coolant choice.

The case is also a regulated unit in the US: a homogeneous case — one National Drug Code, one lot, sealed — must carry the product identifier in a linear or 2D barcode, so the case packer needs its own print station. In the EU, aggregating unit codes to a case or pallet is voluntary and agreed between trading partners, not required. Downstream of that, case packing, stretch wrapping and palletizing robots run exactly as they do on a food line; the pharma-specific requirements are all upstream.

Pharmaceutical Packaging by Material

Six materials cover nearly all pharmaceutical packaging, and each maps to a fixed set of components: glass for ampoules, bottles, vials, syringes and cartridges; plastics for closures, bottles, bags, tubes and the laminates in blisters and sachets; aluminium for collapsible tubes, foils, cans and pressurised containers; rubber for closures and plungers; cardboard for cartons and display units; paper for labels and leaflets.

Glass is the default for parenterals and the first choice for many oral products because it is inert and impermeable. It comes in three pharmacopoeial types graded by hydrolytic resistance:

  • Type I (typically borosilicate): most parenteral and non-parenteral products.
  • Type II (typically surface-treated soda-lime): acidic and neutral aqueous products; alkaline parenterals only where stability data support it.
  • Type III (typically soda-lime): not normally used for parenterals or powders for injection.

One prior to drop: since the October 2023 revision of USP ⟨660⟩ the three types are defined by performance rather than composition, so a container labelled Type I is no longer borosilicate by definition — it is a container that passed the Type I hydrolytic-resistance test.

Plastics are unbreakable, collapsible and light, which is why they take the bottles, closures, bags for parenteral solutions and tubes, and why they are the forming web of every blister and the body of every sachet laminate. Their weakness is permeability, and that is where the material decision for solid oral doses is made.

How much the film matters is shown by a four-lab consortium test of blister structures at 40 °C/75 % RH. A plain 200 µm PVC blister let through roughly 3 mg of water per cavity per day; PVC coated with 60 gsm PVdC cut that to roughly a quarter, PVC laminated with 51 µm Aclar to roughly a twentieth, and cold-form aluminium foil showed no measurable gain at all. Sachet and stick pack laminates follow the same ordering — plain film, then barrier-coated film, then a structure with an aluminium layer — so a moisture-sensitive powder is a foil-laminate job.

Water vapour transmission per blister cavity at 40 °C/75 % RH, four-lab PQRI study, lab-to-lab range (mg/cavity/day)
200 µm PVC
2.978–3.183 mg/cavity/day
200 µm PVC / 60 gsm PVdC
0.789–0.882 mg/cavity/day
200 µm PVC / 51 µm Aclar
0.136–0.152 mg/cavity/day
Cold-form aluminium foil (no measurable gain)
0 mg/cavity/day

Aluminium plays two separate roles. As a container material it is used only for non-parenteral products — collapsible tubes, foil and cold-form blisters, cans and aerosol cylinders — and its strength, gas impermeability and shatter resistance make it the material for pressurised containers. On parenteral vials it appears as the cap that crimps the rubber stopper in place; once removed it cannot be repositioned, which is what makes the crimp a tamper-evident closure.

Rubber is for closures that have to be pierced by a needle — vial stoppers, infusion closures, syringe plungers — and it is the component most often behind an incompatibility between drug and package, so the elastomer is selected against the product rather than taken from stock. Closures that will never be pierced are moulded from polyethylene or polypropylene instead.

Cardboard and paper make the carton, display unit, label and leaflet. None of them touches the product, but printed components are treated as critical to the product’s conformity with its labelling, so they are stored and issued under the same control as any other batch material.

Common Packaging Systems by Pharmaceutical Form

Tablets and capsules go in blisters, strips or bottles; oral liquids in bottles; single-dose powders and granules in sachets and stick packs; parenterals in ampoules, vials, prefilled syringes, cartridges or bags; semi-solids in tubes; and device-delivered forms in the device itself. The dosage form fixes the system almost completely; what remains to decide is the material inside it.

  • Tablets: blisters, strips or bottles, well-closed and protected from light, moisture and crushing; moisture-sensitive forms such as effervescent tablets go in tightly closed containers or high-barrier packs, with a desiccant where needed.
  • Capsules: the same blister or bottle systems, with added protection from excessive dryness as well as moisture, from microbial contamination, and from temperatures above 30 °C.
  • Oral liquids: glass or plastic bottles with a screw neck for syrups or a drop-dispensing neck for drops, glass first where compatibility is in doubt.
  • Oral powders and granules: single-dose sachets and stick packs from a form-fill-seal machine, laminate chosen for moisture barrier; multi-dose quantities in bottles or jars.
  • Parenterals: glass ampoules, vials, bottles, prefilled syringes and cartridges, or plastic bottles and bags for large-volume solutions; multi-dose vials need an elastomer closure that reseals after the needle is withdrawn, and light-sensitive substances go in coloured glass.
  • Topical semi-solids: collapsible metal or plastic tubes for creams, gels and ointments, stored at no more than 25 °C; nasal, aural, vaginal and rectal preparations need a container adapted to the site of application or a supplied applicator.
  • Device-delivered forms: prefilled syringes, pen cartridges, droppers, transdermal systems, pumps and aerosol sprays, where the device is the primary pack and anything pressurised is metal.

Conclusion

Three layers, three rule sets. The primary container is decided by the dosage form and the barrier it needs, which makes it a materials decision as much as a format one. The carton is decided by the market’s serialization and tamper-evidence rules, which put print-and-verify on the cartoner. The transport layer is decided by the product’s temperature class and, for US product, by case-level serialization.

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Soontact provides complete packaging solutions for manufacturers worldwide. Contact our packaging engineers to discuss your specific products, production volumes, and packaging material requirements.

    We offer machine demonstrations, application testing, and detailed proposals that address your particular operational needs.

    Get Your Custom Packaging Solution

    Tell us about your product and production needs. Our engineers will recommend the right machine configuration for your application.

    We only use your details to reply to this request.